8
425
ELECTRIC
E
GAS
G
OIL
O
®
NeW
2 Heat / 2 Cool
User's Manual
Quick Start
Installation
HEAT PUMP
H
Application
The Robertshaw 8425 is a multi-stage thermostat designed to control
24 VAC heat pump systems.
Features
Large backlit display
Adjustable 1
st
stage temperature differential: 1.0°F to 3.0°F (0.5°C to
1.5°C)
Adjustable 2
nd
stage temperature differential: 1.0°F to 6.0°F (0.5°C to
3.0°C)
Adjustable 2
nd
stage delay (10-40 minutes)
Compressor short cycle protection
Accuracy within ±1°
Zone system compatible as a master thermostat
Permanent memory retention
Fahrenheit/Celsius display option
Adjustable from 45°F to 90°F (7°C - 32°C)
Quick wire terminal block
1
110-1090B
110-1090B.qxd 3/4/05 3:58 PM Page 1
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - User's Manual

DIGITAL NON-PROGRAMMABLE THERMOSTAT8425ELECTRICEGASGOILO®NeW2 Heat / 2 Cool User's ManualQuick StartInstallationHEAT PUMPHApplicationThe Robertsh

Page 2 - Recycling Thermostat

108. Wait five seconds or press and the display will switch to the fil-ter monitor setting.9. CHECK FILTER and the length of hours forthe filter moni

Page 3 - WARNING:

Step 5: TroubleshootingSymptom Remedy Thermostat does not turn on system.Check wiring (see Installationsection). If problems with thermostat cannot be

Page 4 - Figure 4

Two Year Limited WarrantyInvensys Controls Americas warrants to the original contractorinstaller, or to the original consumer user, each new Robertsha

Page 5 - Wiring Diagrams

WARNING:• Always turn off power at main fuse or circuit breaker panel beforeinstalling, removing, cleaning, or servicing thermostat.• Read all the inf

Page 6

WARNING:In heat pump applications, do not connect anything to the W1terminal. When switched to HP mode, W1 is connected internallyto Y1 on the thermo

Page 7 - TERMINAL LEGEND - 8425

4. Remove the cover using a coin or screwdriver (Figure 3). Set aside.5. Place thermostat against the wall at desired location. Make surewires will fe

Page 8

5HotHeatingControlCoolingControlTransformerTHERMOSTATW1CRY1GOB24 VAC120 VACHEAT/COOL4-WIRESINGLE TRANSFORMERFanControlY2W2/EHotHeatingControlTransform

Page 9 - ♦ Temperature Differential

6HotCompressorContactorTransformer24 VAC120 VACHEAT PUMP WITHCOOL ACTIVEREVERSING VALVEW1Y1BGOTHERMOSTATNOTE: Make sure the HP swtich is in the HP p

Page 10 - Backlit Display

15. Set the Electric/Gas switch to either GAS for a gas/oil heating system or ELEC for an electric heating system (Figure 5).16. Set the HP option swi

Page 11 - Step 5: Troubleshooting

8Step 3: Testing the ThermostatWARNING: DO NOT SHORT (JUMPER) ACROSS TERMINALS OF GAS VALVE OR SYSTEM CONTROL TO TEST OPERATION. THIS WILLDAMAGE THE T

Page 12 - United States of America

Step 4: Customizing the Thermostat♦ SettingsSystemCool: The thermostat controls the cooling.Off: The heating and cooling systems are off.Heat: The the