Robertshaw 9600 User Manual Page 1

Browse online or download User Manual for Thermostats Robertshaw 9600. Robertshaw 9600 User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
1
Installation Guide
IMPORTANT SAFETY INFORMATION WARNING:
Always turn off power at the main power source by unscrewing
fuse or switching circuit breaker to the off position before installing,
removing, cleaning, or servicing thermostat.
Read all of the information in this manual before installing or
programming this thermostat.
This is a 24V AC low voltage thermostat. Do not install on voltages
higher than 30V AC.
All wiring must conform to local and national building and electrical
codes and ordinances.
Do not short (jumper) across terminals on the gas valve or at the
system control to test installation. This will damage the thermostat
and void the warranty.
110-653C
5 - 2 Day Programmable
1 Heat / 1 Cool
W
A
R
R
A
N
T
Y
INTEGRATED COMFORT SOLUTIONS
DIGITAL
PROGRAMMABLE
THERMOSTAT
9600
User’s Manual
Quick Start
Installation and
Programming
®
ELECTRIC
E
GAS
G
110-653C
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - User’s Manual

1Installation GuideIMPORTANT SAFETY INFORMATION WARNING:•Always turn off power at the main power source by unscrewingfuse or switching circuit breaker

Page 2

TroubleshootingSymptom RemedyThermostat does not turn Check wiring.on system. (See INSTALLATION)Check fuse. Replace with 2 ampSlo-Blo fuse if fuse has

Page 3 - Figure 2

Wiring DiagramsThe following is just a sample of the most common types of HVAC sys-tems. Refer to your system’s installation manual for wiring informa

Page 4 - MOUNTING HOLES

FIVE-YEAR LIMITED WARRANTYMaple Chase Company warrants to the original contractor installer orto the original consumer user, each new Robertshaw therm

Page 5 - SET PROG/MAN

Features• Four setpoints for weekday programming—two setpoints for weekend comfort.•Two AA ENERGIZER brand batteries retain program memory evenduring

Page 6 - COOL-OFF-HEAT

Figure 1Installing Item 9600 ThermostatNOTE: FOR NEW INSTALLATIONS, MOUNT THERMOSTAT ON AN INSIDE WALL, 4-5 FEETABOVE THE FLOOR. DO NOT INSTALL BEHIND

Page 7

Figure 37. Drill the marked holes using a 3/16” drill bit. Note: Enclosed plasticanchors do not require a drilled hole for drywall.8. Tap plastic anch

Page 8 - T PROG/MAN

13. Install two AA ENERGIZER brand batteries or equivalent into batterycompartment. Be sure to match positive (+) ends of batteries withpositive (+) b

Page 9

3. Press Pressto changetemperature differential**THE TEMPERATURE DIFFERENTIAL IS FACTORY PRESET AT 1°. THIS MEANSTHAT WHENEVER THE ROOM TEMPERATURE CH

Page 10 - Troubleshooting

4. Press SET.5. Press  or  to change MORN temperature.6. Repeat Steps 2-5 for DAY, EVE, and NITE.7. Shift COOL-OFF-HEAT switch to HEAT position.8. R

Page 11 - Wiring Diagrams

Temporary Program OverrideTo temporarily increase or decrease temperature:Press  or :The thermostat will automatically return to the program at the

Page 12 - FIVE-YEAR LIMITED WARRANTY

To Test ThermostatWARNING: DO NOT SHORT (JUMPER) ACROSS TERMINALS OF GASVALVE OR SYSTEM CONTROL TO TEST OPERATION. THIS WILL DAMAGETHE THERMOSTAT AND

Comments to this Manuals

No comments