Robertshaw 9801i2 Specifications Sheet Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
191 E. North Avenue
Carol Stream Illinois 60188 USA
Customer Service Telephone 1.800.304.6563
Customer Service Facsimile 1.800.426.0804
Invensys™, Robertshaw
®
and Simply the Right Choice™ are trademarks of
Invensys plc., its subsidiaries and/or affiliated companies. All other brands
mentioned may be the trademarks of their respective owners. 5/13 – 150-2318B
9801i2 9825i2
Braeburn
®
5400
Honeywell TH8321U1006
White-Rodgers 1F97-391 1F95-391
Carrier TP-PRH01-A
Lux TX1500E PSPHA732
Technical Specifications Feature Comparison
Terminal Designations
Replacement Chart
Verify specific application requirements before substitution.
Shipping Specifications
DELUXE SERIES
PROGRAMMABLE
THERMOSTATS
9801
i
2
9825
i
2
For Technical Service
Telephone 1.800.445.8299
Facsimile 1.630.260.7294
Indiv. Ctn. Dim.: 6.625” x 4.25” x 1.625” Item 9020i and 9025i Remote Sensors
Master Ctn. Qty.: 6 Indiv. Ctn. Dim.: 2.625” x 1.5625” x 4.4375”
Master Ctn. Dim.: 9.25” x 5.625 x 7.5” Master Ctn. Qty.: 6
Master Ctn. Cu. Ft.: .23 Master Ctn. Dim.: 5.625” x 5.125” x 5.125”
Master Ctn. Wt.: 3.5 lbs. Master Ctn. Cu. Ft.: .09
Max. Pallet Qty.: 1260 Master Ctn. Wt.: .78 lbs.
Max. Pallet Wt.: 785 lbs.
Remote
Indoor
Sensor
24 VAC
Common
Cooling
Relay
Heat Active
Reversing
Valve
Emergency
Heat /
1st Stage Heat
Cool Active
Reversing
Valve
24 VAC
Transformer
Fan
Relay
IS C
Remote
Outdoor
Sensor
OS Y1 B
E/W1
O R
G
System
Fault
Indicator
L
Dehumidify
Relay
D
Humidify
Relay
H
www.RobertshawTstats.com
www.InvensysControls.comvv
©2013 Invensys Controls
Electrical Rating 24 Volt AC (18-30 VAC)
1 amp maximum load per terminal (relay outputs)
3 amp total maximum load (all terminals combined)
Temperature Control Range 45˚- 90˚F (7˚- 32˚C)
Accuracy +/-1.0˚F (+/-0.5˚C)
Power Source 24 VAC
Auto Changeover Deadband Selectable 2˚ to 8˚F
Temporary Temperature Override From 10 minutes to 365 days
Remote Sensor Capable 1 indoor and 1 outdoor sensor
System Configurations 9801i2 - Single-stage gas, oil or electric heating/
cooling systems and single stage heat
pump systems
9825i2 - Multi-stage gas, oil, or electric heating/
cooling systems including multi-stage heat
pump systems
Terminations 9801i2 - OS, IS, C, G, Y1, B, E/W1, O, R, L, H, D
9825i2 - OS, IS, C, G, Y1, B, E/W1, O, R, W2, Y2, L, H, D
Remote
Outdoor
Sensor
OS
Remote
Indoor
Sensor
IS
24 VAC
Common
C
Cooling
Relay
(Stage 1)
Y1
Heat Active
Reversing
Valve
B
Emergency
Heat /
1st Stage Heat
E/W1
Cool Active
Reversing
Valve
O
Heating
Relay
(Stage 2)
W2
System
Fault
Indicator
L
24 VAC
Transformer
R
Cooling
Relay
(Stage 2)
Y2
Dehumidify
Relay
D
Humidify
Relay
H
Fan
Relay
G
9801i2 9825i2
Robertshaw
9800i2 Series
Honeywell
TH8321U1006
White-Rodgers
1F95-391
Menu Driven (Ease of Programming) X
Installation Wizard X
Displays Complete Program X
Adjustable Backlighting X
Cooling System Monitor X
Heating System Monitor X
Multi-Language; capable of up to 3 languages X
1/2 Degree Resolution X
Time of Day Zoning X
LED Status Indicators X
Integrated Fossil Fuel Kit Converter for
Heat Pump Application
X
Events per Day: 2, 4, 6 X
5/2 Program X
24 Hour Program X
Remote Outdoor Sensor X
Customizable Contractor ID X
Adjustable Residual Cooling X X
12 or 24 Hour X X
Dehumidification X X
Humidification X X
5/1/1 Program X X
7-Day Program X X X
Stages: 1H/1C X X X
Stages: 2H/2C X X X
Large Display X X X
Adjustable Timed Override X X X
Adjustable Timed Hold X X X
Automatic Daylight Saving Time Adjustment X X X
Adjustable Temperature Limits X X X
High/Low Balance Points X X X
Adjustable Differential X X X
Adjustable Compressor Short Cycle Protection X X X
Battery Free Memory Retention X X X
Manual Override X X X
Resume X X X
Auto Changeover X X X
Gas/Electric X X X
Single Stage Heat Pump Compatible X X X
Line Powered X X X
Programmable Fan X X X
°F and °C X X X
Air Filter Monitor X X X
Humidifier Pad Monitor X X X
UV Light Monitor X X X
Vacation Setting X X X
O & B Terminals X X X
4 Hour Reserve X X X
Remote Indoor Sensor X X X
Energy Efficient Recovery X X X
Pre-set Program X X X
Hidden Service Level X X X
Security Key Pad X X X
Temperature Recalibration X X X