User Programmable Settings (Default)
During any program changes the display returns back to the operating
display if a button has not been pushed in 10 seconds.
The temperature scale is set to Fahrenheit.
Night light is off.
The first stage differential is 1F degree.
The second stage differential (RS4220) is 2F degrees.
Auto changeover deadband is 3F degrees.
Filter reminder length is off.
Temperature offset is 0 degrees.
The HI heat limit is 90°F (32°C).
The LO cool limit is 45°F (7°C)
The operation mode will be one of the following:
The fan setting is Auto.
The keypad has no password protection.
Refer to the pop up wizard section in the installation manual for a
complete list of factory defaults and contractor settings.
Emergency Heat
Your system may include Emergency Heat. The RS4220 thermostats have
an emergency heat capability for multi stage heat pump systems. To
determine if your system is capable of using emergency heat contact your
contractor. Use the button to enter the EMER mode. An E will be
displayed with the Heat symbol. This mode is used to bypass the heat
pump when it needs servicing or when it cannot keep up with the heat
demand.
Auto Changeover
Auto changeover is the ability of the thermostat to switch automatically
between heating settings and cooling settings. This is useful in Spring and
Fall when the days are warm and the nights are cool. In heat mode if the
room continues to warm beyond a set threshold the thermostat switches
to the cool mode and the associated cooling settings. The reverse is also
true.
As the room temperature changes, the thermostat will call for heating or
cooling as needed. To prevent the heating and cooling systems from
overriding each other, an automatic changeover deadband is used.
The deadband is the number of degrees that the room temperature can
move away from the active setpoint until heating or cooling is called for.
The larger the deadband the more the room temperature will vary.