WARNING: THIS THERMOSTAT MUST BE INSTALLED ONLY BY A PROFESSIONAL CONTRAC-
TOR FAMILIAR WITH AIR CONDITIONING AND HEATING SYSTEMS CONTROLS AND WIRING
.
I
NSTALL ONLY ON 24V AC SYSTEMS. PLEASE READ THIS MANUAL CAREFULLY BEFORE
INSTALLING
.
IMPORTANT SAFETY INFORMATION
WARNING:
• Always turn off power at the main power source by unscrewing the fuse
or switching the circuit breaker to the off position before installing,
removing, cleaning or servicing thermostat.
• Read all of the information in this manual before installing this thermostat.
• This is a 24V AC low-voltage thermostat. Do not install on voltages higher
than 30V AC.
• All wiring must conform to local and national building and electrical
codes and ordinances.
• Do not short (jumper) across terminals on the gas valve or at the system
control to test installation. This will damage the thermostat and void the
warranty.
FEATURES
• Adjustable from 50°F (10°C) to 90°F (32°C)
• Accuracy within ± 2 degrees Fahrenheit
• Heavy duty heat anticipator
• Hermetically sealed contacts
• No separate subbase
1
1 Heat / 1 Cool
INTEGRATED COMFORT SOLUTIONS
MERCURY-FREE
MECHANICAL
THERMOSTAT
9200
User’s Manual
Quick Start
Installation
110-956B
®
ELECTRIC
E
GAS
G
W
A
R
R
A
N
T
Y
O
N
E
Y
E
A
R
1
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - User’s Manual

WARNING: THIS THERMOSTAT MUST BE INSTALLED ONLY BY A PROFESSIONAL CONTRAC-TOR FAMILIAR WITH AIR CONDITIONING AND HEATING SYSTEMS CONTROLS AND WIRING.I

Page 2 - SPECIFICATIONS

10HotCoolingControlFanControlTransformer24 VAC120 VACCOOL ONLY3-WIRESINGLE TRANSFORMERNOTE: Removefactory installed jumperRHTHERMOSTATRCWYBOG

Page 3 - HEAT PUMP APPLICATIONS

11NOTE: Installer must place jumperbetween W and Y terminals.HotFanRelayCompressorContactorTransformer24 VAC120 VACHEAT PUMP WITHHEAT ACTIVEREVERSING

Page 4 - OTHER APPLICATIONS

Maple Chase Company2820 Thatcher RoadDowners Grove, Illinois 60515An Invensys companyUnited States of America12NOTE: Installer must place jumperbetwee

Page 5 - TEMPERATURE

SPECIFICATIONS• Electrical rating:24 volt AC (18-30 VAC) 2 amps max.250-750 millivolts• 0.2 to 1.6 amp heat anticipation• 4700 ohms fixed cooling anti

Page 6 - ONE-YEAR LIMITED WARRANTY

INSTALLING MODEL 9200 THERMOSTATNOTE: FOR NEW INSTALLATIONS, MOUNT THERMOSTAT ON INSIDE WALL, 5 FEET ABOVETHE FLOOR. DO NOT INSTALL BEHIND A DOOR, IN

Page 7 - HEAT/COOL

OTHER APPLICATIONSTo power a damper motor or auxiliary circuit that requires continuouspower, O and B terminals are provided. (For example, the damper

Page 8 - TWO TRANSFORMER

1. Place the HEAT-OFF-COOLswitch into the COOL position2. Adjust the temperature lever until the indicator is at least 3° belowthe room temperature. T

Page 9

TROUBLESHOOTINGIf problems cannot be solved, call:Technical Support: (800) 445-8299Monday-Friday 7:30-5:30 CSTFor warranty returns, send thermostat, s

Page 10 - SINGLE TRANSFORMER

7WIRING DIAGRAMSThe following pages show samples of the most common types of HVACsystems. Refer to your system’s installation manual for wiring inform

Page 11 - REVERSING VALVE

8HeatingControl(COOLING)Transformer(HEATING)TransformerHot120 VAC 24 VAC24 VACHot120 VACCoolingControlHEAT/COOL5-WIRETWO TRANSFORMERNOTE: Remove facto

Page 12 - COOL ACTIVE

9HotHeatingControlFanControlTransformer24 VAC120 VACHEAT ONLY3-WIRESINGLE TRANSFORMERTHERMOSTATRHRCWYBOGFactory-InstalledJumperHotHeatingControlTransf